Which locking element performs best? For fifteen years, laboratories on every continent have answered that question on a Vibrationmaster desktop instrument.
Standardised Junker testing to DIN 65151, DIN 25201-4 and ISO 16130 — vibration testing, torque and clamping force analysis, and the loosening curves that settle the argument.
Small footprint. Quiet operation. Certification-grade results, beside your desk.
J123
The instrument the fastener world knows best, in its latest generation. The J123 tests fasteners from M3 to M12 metric and #4 to 1/2″ imperial, serving the small screws of consumer electronics as readily as standard machine bolts. Vibration testing and torque–clamping force analysis in one instrument, run from any browser through the Vibrationmaster Test Suite.
Request details
J161
The same instrument, built for larger joints. Beneath identical covers sits a more powerful drive train and higher sensor capacity, serving fasteners from M5 to M16 metric and #10 to 5/8″ imperial.
Request details
JD10-P
The Desktop Series, highly portable. Testing fasteners from M4 to M10 and #6 to 3/8″, the JD10-P brings professional Junker demonstration and testing to the places decisions are made — customer meetings, trade shows, training rooms. The first units are being built now, together with co-developer partners who are shaping its specification.
Request detailsTechnical features
Testing
| JD10-P | J123 | J161 | |
|---|---|---|---|
| Type | Portable | Desktop | Desktop |
| Methodology | Junker test with displacement-driven transverse vibration | Junker test with displacement-driven transverse vibration | Junker test with displacement-driven transverse vibration |
| Test standards | ISO 16130, DIN 25201-4, DIN 65151 | ISO 16130, DIN 25201-4, DIN 65151 | ISO 16130, DIN 25201-4, DIN 65151 |
| Measurements – Torque vs Load | Real-time visualisation of tightening torque vs clamping force and calculation of µtot and K (Nut Factor) – requires the optional torque sensor | Real-time visualisation of tightening torque vs clamping force and calculation of µtot and K (Nut Factor) – requires the optional torque sensor | Real-time visualisation of tightening torque vs clamping force and calculation of µtot and K (Nut Factor) – requires the optional torque sensor |
| Measurements – Torque vs Angle | Not available | Real-time visualisation of tightening torque vs tightening angle – requires the optional torque angle sensor | Real-time visualisation of tightening torque vs tightening angle – requires the optional torque angle sensor |
| Measurements – Vibration test | Real-time visualisation of the loosening curve — clamping force versus cycles — together with displacement and frequency. | Real-time visualisation of the loosening curve — clamping force versus cycles — together with displacement, transverse shear force and frequency. | Real-time visualisation of the loosening curve — clamping force versus cycles — together with displacement, transverse shear force and frequency. |
| Fastener sizes | M4 to M10 and #6 to 3/8″ UTS | M3 to M12 and #4 to 1/2″ UTS | M5 to M16 and #10 to 5/8″ UTS |
| Maximum clamping force | 40,000 N (9,000 lbf) | 50,000 N (11,200 lbf) | 80,000 N (18,000 lbf) |
| Maximum transverse shear force | 7,500 N (1,690 lbf) | 10,000 N (2,250 lbf) | 15,000 N (3,370 lbf) |
| Displacement | Manually set in 0.05 mm increments, from ±0.15 to ±1.00 mm | Manually set in 0.05 mm increments, from ±0.05 to ±1.25 mm | Manually set in 0.05 mm increments, from ±0.25 to ±1.60 mm |
| Frequency | Electronically adjustable during operation, 0 to 12.5 Hz | Electronically adjustable during operation, 0 to 12.5 Hz | Electronically adjustable during operation, 0 to 12.5 Hz |
JD10-P
- Type
- Portable
- Methodology
- Junker test with displacement-driven transverse vibration
- Test standards
- ISO 16130, DIN 25201-4, DIN 65151
- Measurements – Torque vs Load
- Real-time visualisation of tightening torque vs clamping force and calculation of µtot and K (Nut Factor) – requires the optional torque sensor
- Measurements – Torque vs Angle
- Not available
- Measurements – Vibration test
- Real-time visualisation of the loosening curve — clamping force versus cycles — together with displacement and frequency.
- Fastener sizes
- M4 to M10 and #6 to 3/8″ UTS
- Maximum clamping force
- 40,000 N (9,000 lbf)
- Maximum transverse shear force
- 7,500 N (1,690 lbf)
- Displacement
- Manually set in 0.05 mm increments, from ±0.15 to ±1.00 mm
- Frequency
- Electronically adjustable during operation, 0 to 12.5 Hz
J123
- Type
- Desktop
- Methodology
- Junker test with displacement-driven transverse vibration
- Test standards
- ISO 16130, DIN 25201-4, DIN 65151
- Measurements – Torque vs Load
- Real-time visualisation of tightening torque vs clamping force and calculation of µtot and K (Nut Factor) – requires the optional torque sensor
- Measurements – Torque vs Angle
- Real-time visualisation of tightening torque vs tightening angle – requires the optional torque angle sensor
- Measurements – Vibration test
- Real-time visualisation of the loosening curve — clamping force versus cycles — together with displacement, transverse shear force and frequency.
- Fastener sizes
- M3 to M12 and #4 to 1/2″ UTS
- Maximum clamping force
- 50,000 N (11,200 lbf)
- Maximum transverse shear force
- 10,000 N (2,250 lbf)
- Displacement
- Manually set in 0.05 mm increments, from ±0.05 to ±1.25 mm
- Frequency
- Electronically adjustable during operation, 0 to 12.5 Hz
J161
- Type
- Desktop
- Methodology
- Junker test with displacement-driven transverse vibration
- Test standards
- ISO 16130, DIN 25201-4, DIN 65151
- Measurements – Torque vs Load
- Real-time visualisation of tightening torque vs clamping force and calculation of µtot and K (Nut Factor) – requires the optional torque sensor
- Measurements – Torque vs Angle
- Real-time visualisation of tightening torque vs tightening angle – requires the optional torque angle sensor
- Measurements – Vibration test
- Real-time visualisation of the loosening curve — clamping force versus cycles — together with displacement, transverse shear force and frequency.
- Fastener sizes
- M5 to M16 and #10 to 5/8″ UTS
- Maximum clamping force
- 80,000 N (18,000 lbf)
- Maximum transverse shear force
- 15,000 N (3,370 lbf)
- Displacement
- Manually set in 0.05 mm increments, from ±0.25 to ±1.60 mm
- Frequency
- Electronically adjustable during operation, 0 to 12.5 Hz
Electronics
| JD10-P | J123 | J161 | |
|---|---|---|---|
| Signal conditioning | SenseSignal | SenseSignal | SenseSignal |
| Control and data acquisition | SenseControl | SenseControl | SenseControl |
| UI processor | SenseCom | SenseCom | SenseCom |
| User interface | Vibrationmaster Test Suite, browser-based | Vibrationmaster Test Suite, browser-based | Vibrationmaster Test Suite, browser-based |
| Connectivity | RJ45 Ethernet (wired) or wireless connection | RJ45 Ethernet (wired) or wireless connection | RJ45 Ethernet (wired) or wireless connection |
JD10-P
- Signal conditioning
- SenseSignal
- Control and data acquisition
- SenseControl
- UI processor
- SenseCom
- User interface
- Vibrationmaster Test Suite, browser-based
- Connectivity
- RJ45 Ethernet (wired) or wireless connection
J123
- Signal conditioning
- SenseSignal
- Control and data acquisition
- SenseControl
- UI processor
- SenseCom
- User interface
- Vibrationmaster Test Suite, browser-based
- Connectivity
- RJ45 Ethernet (wired) or wireless connection
J161
- Signal conditioning
- SenseSignal
- Control and data acquisition
- SenseControl
- UI processor
- SenseCom
- User interface
- Vibrationmaster Test Suite, browser-based
- Connectivity
- RJ45 Ethernet (wired) or wireless connection
Design
| JD10-P | J123 | J161 | |
|---|---|---|---|
| Designer | Morten Schiff @ Vibrationmaster S.à r.l. | Morten Schiff @ Vibrationmaster S.à r.l. | Morten Schiff @ Vibrationmaster S.à r.l. |
| Materials | High-strength aluminium, carbon fibre, recycled wood | High-strength aluminium, carbon fibre, recycled wood | High-strength aluminium, carbon fibre, recycled wood |
| Dimensions | – | L 434 x W 186 x H 307 mm | L 434 x W 186 x H 307 mm |
| Weight | – | approx. 17 kg (38 lbs) | approx. 19 kg (42 lbs) |
| Sound pressure level | < 58 dB(A) at 1 m distance at maximum test frequency without sample | < 60 dB(A) at 1 m distance at maximum test frequency without sample | < 60 dB(A) at 1 m distance at maximum test frequency without sample |
| Machine approval | CE, UL compliant | CE, UL compliant | CE, UL compliant |
JD10-P
- Designer
- Morten Schiff @ Vibrationmaster S.à r.l.
- Materials
- High-strength aluminium, carbon fibre, recycled wood
- Dimensions
- –
- Weight
- –
- Sound pressure level
- < 58 dB(A) at 1 m distance at maximum test frequency without sample
- Machine approval
- CE, UL compliant
J123
- Designer
- Morten Schiff @ Vibrationmaster S.à r.l.
- Materials
- High-strength aluminium, carbon fibre, recycled wood
- Dimensions
- L 434 x W 186 x H 307 mm
- Weight
- approx. 17 kg (38 lbs)
- Sound pressure level
- < 60 dB(A) at 1 m distance at maximum test frequency without sample
- Machine approval
- CE, UL compliant
J161
- Designer
- Morten Schiff @ Vibrationmaster S.à r.l.
- Materials
- High-strength aluminium, carbon fibre, recycled wood
- Dimensions
- L 434 x W 186 x H 307 mm
- Weight
- approx. 19 kg (42 lbs)
- Sound pressure level
- < 60 dB(A) at 1 m distance at maximum test frequency without sample
- Machine approval
- CE, UL compliant
Power
| JD10-P | J123 | J161 | |
|---|---|---|---|
| Power supply | Single-phase 100 V-230 V, 50-60 Hz | Single-phase 100 V-115 V / 230 V, 50-60 Hz | Single-phase 100 V-115 V / 230 V, 50-60 Hz |
| Power consumption | 10 A at 110 V-115 V / 5 A at 230 V | 12 A at 110 V-115 V / 6 A at 230 V | 15 A at 110 V-115 V / 8 A at 230 V |
JD10-P
- Power supply
- Single-phase 100 V-230 V, 50-60 Hz
- Power consumption
- 10 A at 110 V-115 V / 5 A at 230 V
J123
- Power supply
- Single-phase 100 V-115 V / 230 V, 50-60 Hz
- Power consumption
- 12 A at 110 V-115 V / 6 A at 230 V
J161
- Power supply
- Single-phase 100 V-115 V / 230 V, 50-60 Hz
- Power consumption
- 15 A at 110 V-115 V / 8 A at 230 V
Options
| JD10-P | J123 | J161 | |
|---|---|---|---|
| SenseVision AI Vision Rotational Self-Loosening Angle Sensor | Not available | Optional | Optional |
| High-Resolution Low-Range Clamping Force Sensor for Small Fasteners | Not available | Optional | Optional |
| Automated Multi-Parameter Programmable Tightening Tool | Not available | Optional | Optional |
JD10-P
- SenseVision AI Vision Rotational Self-Loosening Angle Sensor
- Not available
- High-Resolution Low-Range Clamping Force Sensor for Small Fasteners
- Not available
- Automated Multi-Parameter Programmable Tightening Tool
- Not available
J123
- SenseVision AI Vision Rotational Self-Loosening Angle Sensor
- Optional
- High-Resolution Low-Range Clamping Force Sensor for Small Fasteners
- Optional
- Automated Multi-Parameter Programmable Tightening Tool
- Optional
J161
- SenseVision AI Vision Rotational Self-Loosening Angle Sensor
- Optional
- High-Resolution Low-Range Clamping Force Sensor for Small Fasteners
- Optional
- Automated Multi-Parameter Programmable Tightening Tool
- Optional
Applications
| JD10-P | J123 | J161 | |
|---|---|---|---|
| R&D product development | 3 of 5 | 4 of 5 | 4 of 5 |
| Bolted joint design validation | 1 of 5 | 3 of 5 | 3 of 5 |
| Fastener benchmarking | 3 of 5 | 4 of 5 | 5 of 5 |
| Certification for OEM supply | 3 of 5 | 4 of 5 | 5 of 5 |
| New fastener product launch | 4 of 5 | 4 of 5 | 5 of 5 |
| Customer reassurance | 4 of 5 | 4 of 5 | 5 of 5 |
| Tradeshow demonstration | 5 of 5 | 4 of 5 | 4 of 5 |
| Sales meeting presentation | 5 of 5 | 4 of 5 | 4 of 5 |
| Mechanical engineering classes | 5 of 5 | 4 of 5 | 4 of 5 |
| Professional fasteners training | 4 of 5 | 5 of 5 | 5 of 5 |
JD10-P
- R&D product development
- 3 of 5
- Bolted joint design validation
- 1 of 5
- Fastener benchmarking
- 3 of 5
- Certification for OEM supply
- 3 of 5
- New fastener product launch
- 4 of 5
- Customer reassurance
- 4 of 5
- Tradeshow demonstration
- 5 of 5
- Sales meeting presentation
- 5 of 5
- Mechanical engineering classes
- 5 of 5
- Professional fasteners training
- 4 of 5
J123
- R&D product development
- 4 of 5
- Bolted joint design validation
- 3 of 5
- Fastener benchmarking
- 4 of 5
- Certification for OEM supply
- 4 of 5
- New fastener product launch
- 4 of 5
- Customer reassurance
- 4 of 5
- Tradeshow demonstration
- 4 of 5
- Sales meeting presentation
- 4 of 5
- Mechanical engineering classes
- 4 of 5
- Professional fasteners training
- 5 of 5
J161
- R&D product development
- 4 of 5
- Bolted joint design validation
- 3 of 5
- Fastener benchmarking
- 5 of 5
- Certification for OEM supply
- 5 of 5
- New fastener product launch
- 5 of 5
- Customer reassurance
- 5 of 5
- Tradeshow demonstration
- 4 of 5
- Sales meeting presentation
- 4 of 5
- Mechanical engineering classes
- 4 of 5
- Professional fasteners training
- 5 of 5
Below M3?
The smallest screws deserve the most precise instruments. For fasteners below M3, we guide you to the R-Series — engineered for the preloads and tolerances of miniature and small-screw joints.
R-SeriesCertification and comparison, without the wait
Need answers before you need an instrument? Our contract testing programme runs your fasteners on the same Desktop Series instruments, to the same standards.
Contract testing