The new DIN 25201: reference testing and verification testing
Article originally published in FastenerEurAsia, March/April 2013 – part 3 of 4 of Morten Schiff’s series on the new DIN 25201.
Determining the self-loosening behavior of fasteners according to the new DIN 25201 has become a whole lot more complicated. But that means components and products will be a whole lot safer. Vibrationmaster CEO Morten Schiff describes new reference and verification testing requirements in this third in a series of four articles about the new DIN 25201.
Junker Testing’s new requirements: reference tests
The previous test regime under DIN 65151 only required a single test cycle to determine the self-loosening behavior of the fastener under test. Not only does the new DIN 25201 require additional test equipment, such as a washer, but it also introduces two new test cycles: reference testing and verification testing.
To start the reference test, the fastener must be placed securely in a Junker Test Bench and the displacement varied until the point when it self-loosens after 300 load cycles, plus or minus 100 load cycles at a frequency of 12.5 Hz. Once this initial reference test displacement has been discovered, the fastener should undergo three subsequent reference tests to ensure that the effective displacement is correct and the results are consistent. This means running the same test again, but with fresh fastenings and washers and under exactly the same conditions. Maintaining consistency is very important, because the test report will require the exact test conditions to be precisely recorded.
Conducting the verification tests
The objective of the next stage is to test the performance of the securing element of the fastener and to find out at what point it starts to loosen. There must be 12 verification tests for each set of measurements recorded from the reference test. This is a significantly greater requirement than with the old DIN 65151. Each verification test must be performed on the fastener, with its locking mechanism in place, until it either loosens or 2,000 load cycles have been completed. The 12 tests must measure and record the following variables:
- The pre-stressing force
- The transverse displacement under load
- The number of load cycles.
Crucially, the test results can only be used for the specific diameter of the fastener being tested. This might seem like an obvious point, but under the old testing DIN 65151 testing regime, which did not impose this requirement, many manufacturers only tested the securing effect of their locking device on one diameter of their fastener range. It was then assumed that the results of the Junker Test on a 5/16 bolt, for example, were probably OK to apply to a 7/16 bolt. This is no longer acceptable, meaning fasteners rated on this basis will fail the new DIN 25201. And it also means that many manufacturers’ product ranges will require retesting to the new standard, if they are to remain on specification lists.
Assessing the securing effect
Having completed the 12 verification tests, the next stage is to plot the results of the pre-stressing force against the number of load cycles. The securing effect is then assessed according to whether the bolt failed before 2,000 load cycles were completed or on the percentage loss of the pre-stressing force after 2,000 load cycles.
The DIN says that the securing effect of the locking mechanism is considered to be ‘adequate’ if there is 80% or more of the pre-stressing force, from when the test started, remaining after 2,000 load cycles. And, based on the plot of the pre-stressing force against the number of load cycles, the pre-stressing force curve must show that it is unlikely that the fastener would have failed if the test continued beyond 2,000 cycles.
Next in the series – Part 4: New Junker fastener testing reporting requirements can be used globally.
References
- DIN 65151: 2002-08 Dynamic testing of the locking characteristics of fasteners under transverse loading conditions (vibration test), Deutsches Institut für Normung e.V., Berlin 2002
- DIN 25201-4: 2010-03 Annex B Test specification for demonstrating the resistance to self-loosening of secured bolted joints, Deutsches Institut für Normung e.V., Berlin 2010